{"id":878,"date":"2023-12-01T10:57:32","date_gmt":"2023-12-01T10:57:32","guid":{"rendered":"https:\/\/visioncare.biz\/wp\/?post_type=product&#038;p=878"},"modified":"2023-12-01T10:59:45","modified_gmt":"2023-12-01T10:59:45","slug":"oculus-imagecam-3","status":"publish","type":"product","link":"https:\/\/visioncare.biz\/?product=oculus-imagecam-3","title":{"rendered":"OCULUS ImageCam\u00ae 3"},"content":{"rendered":"<h3><span style=\"color: #3366ff;\">Highlights<\/span><\/h3>\n<div id=\"contentProdukte\">\n<div id=\"inhalt\">\n<div class=\"produktseite_text_bild\">\n<div class=\"ps_bild_links\">\n<div class=\"ps_bild\"><img fetchpriority=\"high\" decoding=\"async\" class=\"alignleft\" src=\"https:\/\/www.oculus.de\/fileadmin\/images\/produktbilder\/imagecam3\/highlights\/oculus_imagecam_on_sl_ic.jpg\" alt=\"OCULUS ImageCam\u00ae 3: image documentation system for slit lamps\" width=\"391\" height=\"428\" \/><\/div>\n<h4 class=\"ps_beschreibung\"><span style=\"color: #3366ff;\">The OCULUS ImageCam<sup>\u00ae<\/sup>\u00a03<\/span><\/h4>\n<\/div>\n<div class=\"ps_text_rechts\">\n<ul>\n<li>Small and lightweight \u2013 The beam splitter and the camera unit are extremely small and lightweight, making your routine slit-lamp diagnostics light work in the truest sense of the word.<\/li>\n<li>Swivelling prism \u2013 The coupling prism of the ImageCam\u00ae 3 beam splitter can be completely swung in and out of the slit lamp\u2019s beam path using a lever.<\/li>\n<li>Universally adaptable \u2013 The OCULUS ImageCam\u00ae 3 system is suitable for most slit lamps thanks to its versatile adaptation options.<\/li>\n<li>Super light sensitive USB 3.0 camera \u2013 Only a powerful camera can produce low-noise images in as difficult conditions as prevail around the eye.<\/li>\n<li>Intuitive Software \u2013 The software is easy to use, presenting the images recorded in an attractive frame.<\/li>\n<li>Image from video \u2013 The ImageCam\u00ae 3 enables you to record your entire slit lamp examination on a video from which you can then select the best frames for your archive. That spells good-bye to blurred images and consistently high-class images for your documentation.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h3><span style=\"color: #3366ff;\">Functions<\/span><\/h3>\n<p>Image documentation using the OCULUS ImageCam\u00ae 3<\/p>\n<p><img decoding=\"async\" class=\"alignleft\" src=\"https:\/\/www.oculus.de\/fileadmin\/images\/produktbilder\/imagecam3\/funktionen\/oculus_imagecam_hornhautdegeneration.jpg\" alt=\"Image documentation using the OCULUS ImageCam\u00ae 3\" width=\"452\" height=\"282\" \/><\/p>\n<div class=\"produktseite_text_bild\">\n<div class=\"ps_bild_links\">\n<h4 class=\"ps_beschreibung\"><span style=\"color: #3366ff;\">A Picture is Worth More Than a Thousand Words<\/span><\/h4>\n<\/div>\n<div class=\"ps_text_rechts\">\n<p><b>Application Examples:<\/b><\/p>\n<ul>\n<li>Documentation of the anterior and posterior eye segment<\/li>\n<li>Image use for better patient education<\/li>\n<li>Fluorescein imaging for contact lens fitting<\/li>\n<li>Follow-ups<\/li>\n<li>Storage and archiving of findings<\/li>\n<li>Single image mode \u2013 Pigmentation<\/li>\n<li>Four picture mode \u2013 Lid surgery follow-up<\/li>\n<li>Single image mode \u2013 Tear meniscus<\/li>\n<li>Four picture mode \u2013 Corneal degeneration<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<div class=\"produktseite_text_bild\">\n<div class=\"ps_bild_rechts\">\n<div class=\"ps_bild\"><img decoding=\"async\" class=\"alignright\" src=\"https:\/\/www.oculus.de\/fileadmin\/images\/produktbilder\/imagecam3\/funktionen\/oculus_imagecam_fluobilder_vergleich.jpg\" alt=\"Keratograph and ImageCam\u00ae 3 software linked together\" width=\"469\" height=\"352\" \/><\/div>\n<\/div>\n<\/div>\n<div><\/div>\n<div><\/div>\n<h4><span style=\"color: #3366ff;\">Combine the ImageCam<\/span><sup style=\"color: #3366ff;\">\u00ae<\/sup><span style=\"color: #3366ff;\">\u00a03 with the OCULUS Keratograph<\/span><\/h4>\n<div class=\"produktseite_text_bild\">\n<div class=\"ps_bild_rechts\">\n<div>\n<p>The ImageCam<sup>\u00ae<\/sup>\u00a03 software can be linked with the Keratograph software. You can compare simulated fluo-images from the OCULUS Keratograph with the actual fluo-image produced by the slit lamp.<\/p>\n<\/div>\n<div><\/div>\n<div><\/div>\n<div><\/div>\n<div><\/div>\n<div class=\"ps_beschreibung\" style=\"text-align: right;\">Keratograph and ImageCam\u00ae 3 software linked together<\/div>\n<\/div>\n<\/div>\n<div class=\"anchor\"><\/div>\n<div><\/div>\n<div><img loading=\"lazy\" decoding=\"async\" class=\"alignleft\" src=\"https:\/\/www.oculus.de\/fileadmin\/images\/produktbilder\/imagecam3\/funktionen\/serienaufnahmen.jpg\" alt=\"Serial capture mode\" width=\"410\" height=\"205\" \/><\/div>\n<h4><span style=\"color: #3366ff;\">Serial exposures &#8211; the right moment in focus<\/span><\/h4>\n<div class=\"produktseite_text_bild\">\n<div class=\"ps_text_rechts\">\n<p>The ImageCam<sup>\u00ae<\/sup>\u00a03 serial capture mode helps you master the challenge of motion blur and take images with crisp focus.<\/p>\n<\/div>\n<div><\/div>\n<div><\/div>\n<div><\/div>\n<div style=\"text-align: left;\">Serial capture mode<\/div>\n<\/div>\n<div><\/div>\n<div><\/div>\n<div class=\"produktseite_text_bild\">\n<div class=\"ps_bild_rechts\">\n<div class=\"ps_bild\"><img loading=\"lazy\" decoding=\"async\" class=\"alignright\" src=\"https:\/\/www.oculus.de\/fileadmin\/images\/produktbilder\/imagecam3\/funktionen\/belichtungsreihen.jpg\" alt=\"Serial capture with incremental exposure time\" width=\"410\" height=\"204\" \/><\/div>\n<\/div>\n<\/div>\n<h4><span style=\"color: #3366ff;\">Variable exposure times for optimal results<\/span><\/h4>\n<div class=\"produktseite_text_bild\">\n<div class=\"ps_bild_rechts\">\n<div class=\"ps_beschreibung\">\n<p>The ImageCam<sup>\u00ae<\/sup>\u00a03 can automatically change exposure times for 5 consecutive images, allowing you to select the image with the best exposure time.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: right;\">Serial capture with incremental exposure time<\/p>\n<p>&nbsp;<\/p>\n<h3><span style=\"color: #3366ff;\">Technical Data<\/span><\/h3>\n<table cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.oculus.de\/fileadmin\/images\/produktbilder\/imagecam3\/technische_daten\/oculus_imagecam_3_technische_zeichnung.jpg\" alt=\"\" width=\"272\" height=\"320\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<table width=\"605\">\n<tbody>\n<tr>\n<td colspan=\"2\"><strong>Camera<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"262\">Camera<\/td>\n<td width=\"337\">Progressive scan<\/td>\n<\/tr>\n<tr>\n<td width=\"262\">Interface<\/td>\n<td width=\"337\">USB 3.0<\/td>\n<\/tr>\n<tr>\n<td width=\"262\">Shutter system<\/td>\n<td width=\"337\">Global shutter<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table width=\"605\">\n<tbody>\n<tr>\n<td colspan=\"2\"><strong>Beam splitter<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"262\">Splitting ratio<\/td>\n<td width=\"337\">70\/30 (camera\/binocular)<\/td>\n<\/tr>\n<tr>\n<td width=\"262\">Splitting prism<\/td>\n<td width=\"337\">swing-in\/swing-out<\/td>\n<\/tr>\n<tr>\n<td width=\"262\">Aperture (mechanical)<\/td>\n<td width=\"337\">adjustable<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table width=\"605\">\n<tbody>\n<tr>\n<td colspan=\"2\"><strong>Software<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"262\">Image viewer<\/td>\n<td width=\"337\">Image processing, measuring tool, printing and export, camera control<\/td>\n<\/tr>\n<tr>\n<td width=\"262\">Image format<\/td>\n<td width=\"337\">JPG, BMP<\/td>\n<\/tr>\n<tr>\n<td width=\"262\">Video format<\/td>\n<td width=\"337\">AVI, MJPEG<\/td>\n<\/tr>\n<tr>\n<td width=\"262\">Network capability<\/td>\n<td width=\"337\">Central data base with viewer software<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table width=\"605\">\n<tbody>\n<tr>\n<td colspan=\"2\"><strong>Technical specifications<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"262\">Dimensions camera (W x D x H)<\/td>\n<td width=\"337\">29 x 29 x 48 mm (1.1 x 1.1 x 1.9 in)<\/td>\n<\/tr>\n<tr>\n<td width=\"262\">Dimensions beam splitter (W x D x H)<\/td>\n<td width=\"337\">92 x 39 to 55 x 93 mm (3.6 x 1.5 to 2.2 x 3.6 in), depending on model<\/td>\n<\/tr>\n<tr>\n<td width=\"262\">Weight camera<\/td>\n<td width=\"337\">47 g (1.7 oz)<\/td>\n<\/tr>\n<tr>\n<td width=\"262\">Weight beam splitter<\/td>\n<td width=\"337\">335 to 480 g (11.8 to 16.9 oz), depending on model<\/td>\n<\/tr>\n<tr>\n<td width=\"262\">Recommended computer requirements<\/td>\n<td width=\"337\">Intel Core(TM) i5, 256 GB SSD,1 TB SATA, 8 GB RAM, Windows\u00ae 10 Pro, USB 3.0<\/td>\n<\/tr>\n<tr>\n<td width=\"262\">Recommended screen resolution<\/td>\n<td width=\"337\">1920 x 1200 pixel<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table width=\"605\">\n<tbody>\n<tr>\n<td colspan=\"2\"><strong>Slit Lamp Adaptations<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"262\">The ImageCam<sup>\u00ae<\/sup>\u00a03 can be adapted to all common slit lamps available on the market!<\/td>\n<td width=\"337\">The following PDF document gives you an overview of all available adaptions:\u00a0<a href=\"https:\/\/www.oculus.de\/fileadmin\/images\/produktbilder\/imagecam3\/technische_daten\/adaptionen_imagecam3_en_1018.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">S<strong>lit Lamp Adaptions \/ PDF File (146 KB)<\/strong><\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<div class=\"zertifikat_product_page\">\n<div class=\"zertifikat_ce\"><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h3>One of the Smallest Slit Lamp Documentation Systems Available<\/h3>\n<h6>The OCULUS ImageCam\u00ae 3 is one of the world\u2019s smallest image documentation systems and can be adapted to virtually all commercially available slit lamps.<\/h6>\n<p>The slit lamp photos and videos are captured with a high-resolution, digital USB 3.0 camera by simply pressing a foot switch, or, in the \u201edigital ready\u201c versions of OCULUS slit lamps, using the joystick. Complete slit lamp examinations can be recorded as a video sequence, from which the best frames can be selected and saved for documentation of the findings.<\/p>\n","protected":false},"featured_media":991,"comment_status":"open","ping_status":"closed","template":"","meta":{"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"product_cat":[17],"product_tag":[],"class_list":["post-878","product","type-product","status-publish","has-post-thumbnail","product_cat-uncategorized","first","instock","shipping-taxable","product-type-simple","entry","content-bg","loop-entry"],"_links":{"self":[{"href":"https:\/\/visioncare.biz\/index.php?rest_route=\/wp\/v2\/product\/878","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/visioncare.biz\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/visioncare.biz\/index.php?rest_route=\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/visioncare.biz\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=878"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/visioncare.biz\/index.php?rest_route=\/wp\/v2\/media\/991"}],"wp:attachment":[{"href":"https:\/\/visioncare.biz\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=878"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/visioncare.biz\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=878"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/visioncare.biz\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=878"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}