{"id":871,"date":"2023-12-01T10:57:31","date_gmt":"2023-12-01T10:57:31","guid":{"rendered":"https:\/\/visioncare.biz\/wp\/?post_type=product&#038;p=871"},"modified":"2024-03-02T20:37:38","modified_gmt":"2024-03-02T20:37:38","slug":"oculus-park-1","status":"publish","type":"product","link":"https:\/\/visioncare.biz\/?product=oculus-park-1","title":{"rendered":"OCULUS PARK 1\u00ae"},"content":{"rendered":"<div class=\"produktseite_text_bild\">\n<div class=\"ps_bild_links\">\n<h3><span style=\"color: #3366ff;\">HIGHLIGHTS<\/span><\/h3>\n<h4 class=\"ps_beschreibung\"><span style=\"color: #3366ff;\">Up to Three Measurements in a Matter of Seconds<\/span><\/h4>\n<\/div>\n<div class=\"ps_text_rechts\">\n<ul>\n<li>Auto-refractor<\/li>\n<li>Keratometer<\/li>\n<li>Pachymeter (optional)<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<div class=\"produktseite_text_bild\">\n<div class=\"ps_text_links\">\n<h3><\/h3>\n<h4><span style=\"color: #3366ff;\">Contact Lens Database<\/span><\/h4>\n<p>The integrated contact lens database for soft contact lenses (sph, tor, multifocal) supplies a list of recommendations based on the objectively measured data. Individually adjustable parameters, such as subjective refraction, wear duration and contact lens type, allow the patient&#8217;s preferences to be taken into consideration.<\/p>\n<p>&nbsp;<\/p>\n<\/div>\n<div class=\"ps_bild_rechts\">\n<div class=\"ps_bild\"><img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/www.oculus.de\/fileadmin\/images\/produktbilder\/park_1\/highlights\/us\/oculus_park1_contact_lens_database_0714.jpg\" alt=\"\" width=\"410\" height=\"308\" \/><\/div>\n<div class=\"ps_beschreibung\"><\/div>\n<\/div>\n<div>\n<h3><span style=\"color: #3366ff;\">Touchscreen<\/span><\/h3>\n<p>Menu navigation on the touchscreen ensures intuitive and easy operation.<\/p>\n<\/div>\n<\/div>\n<div class=\"anchor\"><\/div>\n<div class=\"produktseite_text_bild\">\n<div class=\"ps_bild_links\">\n<div class=\"ps_bild\"><img decoding=\"async\" src=\"https:\/\/www.oculus.de\/fileadmin\/images\/produktbilder\/park_1\/highlights\/us\/oculus_park1_touchscreen_0714.jpg\" alt=\"\" width=\"410\" height=\"308\" \/><\/div>\n<div class=\"ps_beschreibung\"><\/div>\n<\/div>\n<\/div>\n<div class=\"produktseite_text_bild\">\n<div class=\"ps_text_links\">\n<h3><span style=\"color: #3366ff;\">Automatic Measurement Release<\/span><\/h3>\n<p>The automatic measurement release provides reproducible measuring results in a matter of seconds:<\/p>\n<ul>\n<li>Objective refraction values<\/li>\n<li>Keratometer values<\/li>\n<li>Pachymetry in the apex<\/li>\n<li>Diameter of the cornea<\/li>\n<li>Pupil diameter<\/li>\n<li>Far PD<\/li>\n<\/ul>\n<\/div>\n<div class=\"ps_bild_rechts\">\n<div class=\"ps_bild\"><img decoding=\"async\" src=\"https:\/\/www.oculus.de\/fileadmin\/images\/produktbilder\/park_1\/highlights\/us\/oculus_park1_automatic_measurement_release_us.jpg\" alt=\"\" width=\"410\" height=\"308\" \/><\/div>\n<\/div>\n<\/div>\n<div class=\"anchor\"><\/div>\n<div class=\"produktseite_text_bild\">\n<div class=\"ps_text_rechts\">\n<h3><span style=\"color: #3366ff;\">RED DOT Award &#8211; Design-Prize<\/span><\/h3>\n<p>The PARK 1<sup>\u00ae<\/sup>\u00a0won the RED DOT Award for its slim, ergonomic, space-saving design.<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h3><strong><span style=\"color: #3366ff;\">FUNCTIONS<\/span><\/strong><\/h3>\n<div id=\"contentProdukte\">\n<div id=\"inhalt\">\n<div class=\"produktseite_text_bild\">\n<div class=\"ps_bild_links\">\n<div class=\"ps_bild\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.oculus.de\/fileadmin\/images\/produktbilder\/park_1\/funktionen\/us\/oculus_park1_autorefractometer_eng_0714.jpg\" alt=\"\" width=\"410\" height=\"308\" \/><\/div>\n<div class=\"ps_beschreibung\"><\/div>\n<\/div>\n<div class=\"ps_text_rechts\">\n<h3><span style=\"color: #3366ff;\">Auto-Refractometer<\/span><\/h3>\n<p>Measurement of the objective refraction data in seconds, with reproducible results. Specification of a quality factor provides information about the usability or the quality of the conducted measurement. The reliably determined data come very close to the subjective refraction.<img decoding=\"async\" src=\"https:\/\/www.oculus.de\/fileadmin\/images\/sonstiges\/trans_1px.jpg\" alt=\"\" \/><\/p>\n<\/div>\n<div>\n<div class=\"produktseite_text_bild\">\n<div class=\"ps_text_links\">\n<h3><span style=\"color: #3366ff;\">Keratometer<\/span><\/h3>\n<p>The integrated, distance-independent keratometer guarantees measurement of the central radii with the greatest of accuracy.<\/p>\n<\/div>\n<div class=\"ps_bild_rechts\">\n<div class=\"ps_bild\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.oculus.de\/fileadmin\/images\/produktbilder\/park_1\/funktionen\/us\/oculus_park1_keratometer_eng_0714.jpg\" alt=\"\" width=\"410\" height=\"308\" \/><\/div>\n<div class=\"ps_beschreibung\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div>\n<h3><span style=\"color: #3366ff;\">Pachymeter<\/span><\/h3>\n<p>The optional, non-contact pachymetry is based on Scheimpflug images and makes precise non-contact measurement of the corneal thickness possible.<\/p>\n<ul>\n<li>Measurement of the corneal thickness in the apex and the minimum corneal thickness in the entire measuring area<\/li>\n<li>Measurement of 600 absolute height values on a horizontal 4 mm cut through the apex<\/li>\n<li>Presentation of the corneal thickness profile in the form of a diagram. Automatic adjustment of the scaling of the Pachymetry measurements for better presentation of the individual thicknesses<\/li>\n<li>Pachymetry-based correction of the separately measured intraocular pressure<\/li>\n<\/ul>\n<\/div>\n<div><\/div>\n<div id=\"contentProdukte\">\n<div id=\"inhalt\">\n<div class=\"produktseite_text_bild\">\n<div class=\"produktseite_text_bild\">\n<div class=\"ps_bild_links\">\n<div class=\"ps_bild\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.oculus.de\/fileadmin\/images\/produktbilder\/park_1\/funktionen\/us\/oculus_park1_pachymeter_eng_0714.jpg\" alt=\"\" width=\"410\" height=\"308\" \/><\/div>\n<\/div>\n<div><\/div>\n<\/div>\n<div class=\"produktseite_text_bild\">\n<div class=\"ps_text_links\">\n<h3><span style=\"color: #3366ff;\">Optional Database for Soft Contact Lenses with Fitting Recommendation<\/span><\/h3>\n<ul>\n<li>Fitting recommendation for soft contact lenses (based on the objective refraction, corneal diameter and central corneal radii measurements)<\/li>\n<li>Adaptable list of contact lenses in the unit<\/li>\n<li>The stabilization axis can be taken into account for fitting toric lenses<\/li>\n<li>Over-refraction support<\/li>\n<li>OxiMap<sup>\u00ae<\/sup>\u00a0\u2013 Visualization of the oxygen transmissibility of soft contact lenses<\/li>\n<\/ul>\n<\/div>\n<div class=\"ps_bild_rechts\">\n<div class=\"ps_bild\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.oculus.de\/fileadmin\/images\/produktbilder\/park_1\/funktionen\/oculus_park1_datenbank.jpg\" alt=\"\" width=\"410\" height=\"308\" \/><\/div>\n<div class=\"ps_beschreibung\"><\/div>\n<\/div>\n<div>\n<div class=\"ps_bild_links\">\n<div class=\"ps_beschreibung\"><\/div>\n<\/div>\n<div class=\"ps_text_rechts\">\n<h3><span style=\"color: #3366ff;\">Automatic Measurement Release<\/span><\/h3>\n<p>Thanks to the automatic measurement release, you always get reproducible measuring results. The diameters of the pupil and cornea, and the pupillary distance are determined automatically. Manual measurement is no longer necessary.<\/p>\n<\/div>\n<div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"produktseite_text_bild\">\n<div class=\"ps_bild_links\">\n<div class=\"ps_bild\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.oculus.de\/fileadmin\/images\/produktbilder\/park_1\/funktionen\/us\/oculus_park1_automatic_measurement_release_us.jpg\" alt=\"\" width=\"410\" height=\"308\" \/><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div><\/div>\n<h3><span style=\"color: #3366ff;\">TECHNICAL DATA<\/span><\/h3>\n<div>\n<div class=\"csc-textpic csc-textpic-center csc-textpic-above\">\n<div><\/div>\n<div class=\"csc-textpic-imagewrap csc-textpic-single-image\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.oculus.de\/fileadmin\/images\/produktbilder\/park_1\/technische_daten\/oculus_park1_technische_zeichnung.jpg\" alt=\"Technische Zeichnung des OCULUS PARK 1\" width=\"422\" height=\"285\" \/><\/div>\n<\/div>\n<\/div>\n<div>\n<p>&nbsp;<\/p>\n<table width=\"680\">\n<tbody>\n<tr>\n<td colspan=\"2\"><strong>Pachymeter (P)<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Measuring range<\/td>\n<td width=\"375\">200 bis 1 200 \u03bcm<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Number of evaluated measuring points<\/td>\n<td width=\"375\">600<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Measuring time<\/td>\n<td width=\"375\">Approx. 1 sec.<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Light source<\/td>\n<td width=\"375\">Blue LEDs (455 nm UV-free)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table width=\"680\">\n<tbody>\n<tr>\n<td colspan=\"2\"><strong>Auto-Refractometer (AR)<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Corneal vertex distance (CVD)<\/td>\n<td width=\"375\">0; 10.5; 12; 13.75; 15; 16.5 mm<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Sphere<\/td>\n<td width=\"375\">-20 to +22 dpt (CVD = 12 mm) (choice of 0.01-; 0.12- or 0.25 dpt increments)<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Cylinder<\/td>\n<td width=\"375\">10 dpt (CVD = 12 mm) (choice of 0.01-; 0.12- and 0.25 dpt increments)<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Axis<\/td>\n<td width=\"375\">0\u00b0 to 180\u00b0 (in 1\u00b0 increments)<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Smallest measurable pupil diameter<\/td>\n<td width=\"375\">2.5 mm<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Fixation image<\/td>\n<td width=\"375\">Hot air balloon in a landscape<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<div>\n<table width=\"680\">\n<tbody>\n<tr>\n<td colspan=\"2\"><strong>Keratometer (K)<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Measuring range<\/td>\n<td width=\"375\">9 to 99 dpt<br \/>\n3 to 38 mm<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Accuracy<\/td>\n<td width=\"375\">\u00b1 0.1 dpt<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Reproducibility<\/td>\n<td width=\"375\">\u00b1 0.1 dpt<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table width=\"680\">\n<tbody>\n<tr>\n<td width=\"299\">Far PD<\/td>\n<td width=\"375\">20 to 80 mm (in 1 mm-increments)<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Corneal diameter measuring range<\/td>\n<td width=\"375\">10 to 14 mm (in 0.1 mm-increments)<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Pupil diameter measuring range<\/td>\n<td width=\"375\">1 to 8 mm (in 0.1 mm-increments)<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Auto alignment<\/td>\n<td width=\"375\">Automatic height alignment (y-direction)<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Auto release<\/td>\n<td width=\"375\">Automatic measurement release<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Working distance<\/td>\n<td width=\"375\">Approx. 36 mm (1.4 in)<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Dimensions H x W x D<\/td>\n<td width=\"375\">500 x 265 x 538 mm (19.7 x 10.4 x 21.1 in)<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Weight<\/td>\n<td width=\"375\">12 kg (26.4 lbs)<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Power supply<\/td>\n<td width=\"375\">100 &#8211; 240 V AC, 50 &#8211; 60 Hz<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Printer<\/td>\n<td width=\"375\">Thermal printer<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Display<\/td>\n<td width=\"375\">TFT &#8211; LCD 5.7&#8243; (Touchscreen)<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Interface<\/td>\n<td width=\"375\">USB<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Standard accessories<\/td>\n<td width=\"375\">Printer paper, power cable, dust cover, chin rest paper, USB mini cable<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<h4><a href=\"http:\/\/www.visioncare.biz\/Backup\/Files\/park_1_en.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Download OCULUS PARK1 BROCHURE<\/a><\/h4>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<h3>Pachymeter, Auto-Refractometer, Keratometer<\/h3>\n<h5>The PARK 1<sup>\u00ae<\/sup>\u00a0combines a non-contact pachymeter, auto-refractometer and keratometer in one unit. In addition to the objective refraction, the keratometer values and the pachymetry can be determined with precision in a matter of seconds with the PARK 1<sup>\u00ae<\/sup>.<br \/>\nThe integrated patient data management system facilitates the organization of the data and ensures patient-friendly contact lens fitting. Thanks to its space-saving, compact design, this award-winning unit is ideal for use in every ophthalmology practice.<\/h5>\n","protected":false},"featured_media":952,"comment_status":"open","ping_status":"closed","template":"","meta":{"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"product_cat":[17],"product_tag":[],"class_list":["post-871","product","type-product","status-publish","has-post-thumbnail","product_cat-uncategorized","first","instock","shipping-taxable","product-type-simple","entry","content-bg","loop-entry"],"_links":{"self":[{"href":"https:\/\/visioncare.biz\/index.php?rest_route=\/wp\/v2\/product\/871","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/visioncare.biz\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/visioncare.biz\/index.php?rest_route=\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/visioncare.biz\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=871"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/visioncare.biz\/index.php?rest_route=\/wp\/v2\/media\/952"}],"wp:attachment":[{"href":"https:\/\/visioncare.biz\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=871"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/visioncare.biz\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=871"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/visioncare.biz\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=871"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}