{"id":865,"date":"2023-12-01T10:57:31","date_gmt":"2023-12-01T10:57:31","guid":{"rendered":"https:\/\/visioncare.biz\/wp\/?post_type=product&#038;p=865"},"modified":"2023-12-01T10:58:39","modified_gmt":"2023-12-01T10:58:39","slug":"optopol-pts-920","status":"publish","type":"product","link":"https:\/\/visioncare.biz\/?product=optopol-pts-920","title":{"rendered":"OPTOPOL PTS 920"},"content":{"rendered":"<div>\n<div>\n<h4>ALL STANDARD TESTS<\/h4>\n<p>PTS 920 contains complete set of standard perimetry tests. Variety of threshold algorithms and screening techniques to choose from, always give the right answer for specific medical case. Thanks to wide range of testing point maps organized in radial patterns, stimuli are denser in the center and help to find central scotomas (contrary to popular 30-3 and 24-2). With PTS 920, all special tests like Binocular Driver\u2019s Test, Flicker perimetry and Blue on Yellow* test become fast and easy.<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<div>\n<div>\n<h4>QUICK CENTRAL FIELD THRESHOLDING<\/h4>\n<p>Advanced strategy which utilizes a special testing algorithm, allows quicker examination without loss in result resolution. Radial equivalent of 24-2 and 30-2 field can be tested in less than 3 and 4 minutes respectively. This fast and repeatable procedure provides you with more detailed information than screening strategies in comparable duration. Shorter testing time directly translates not only to higher patient throughput but also to patient comfort and test result reliability.<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<div>\n<div>\n<h4>SUPREME RELIABILITY \u2013 BLINK CONTROL, EYE TRACKING<\/h4>\n<p>PTS 920 features high resolution camera for precise monitoring of patients\u2019 compliance.\u00a0 Blink control mechanism assures that no stimuli are omitted due to normal blinking. Expositions interrupted by blink are repeated, and test is held until the eye is opened again. Constant eye tracking mechanism analyses pupil movement and assures supreme reliability of test results.<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h4>FLEXIBILITY FOR TIME<\/h4>\n<div>\n<p>PTS 920 contains rich library of predefined test fields and programs. Intuitive software provides means of creating custom programs and test point patterns. Custom test settings can be stored and accessed with one mouse click. This helps to save valuable staff time and assures optimum patient flow with minimal effort. Follow-up tests can be performed with ease, by simple selection of base examination and starting the new one. Testing of difficult patients is made easy with PTS 920. Partial test results of not completed test can be stored in patient\u2019s record and continued in the future.<\/p>\n<p>&nbsp;<\/p>\n<h4>NETWORK INTEGRATION<\/h4>\n<\/div>\n<div>\n<div>\n<div>\n<p>PTS 920 built-in networking features assure that all the data can be accessed from anywhere within your network. Networked reviewing stations can display and review data updated in real-time by examination host machine. With networking facilities, PTS 920 provides optimum conditions for undelayed practice workflow.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h4>DICOM, GDT, EMR<\/h4>\n<div>\n<div>\n<div>\n<p>PTS 920 with its out of the box DICOM support, allows seamless integration of perimeter into your DICOM environment. Storing visual field reports on the DICOM image server is made easy with PTS 920. Thanks to DICOM Modality Worklist support\u00a0 operator comfort\u00a0 is increased and the risk of transcription errors eliminated. Besides DICOM, PTS 920 supports also GDT and custom EMR\u2019s based on text file interface. This allows your practice to be up to date with today\u2019s information technology.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h4>VOICE GUIDE\u00a0 ASSISTANCE<\/h4>\n<div>\n<div>\n<div>\n<p>PTS 920 features a user friendly voice guide module. Voice messages assist operator and patient during the examination and help to efficiently complete the test procedure. Thanks to this remarkable feature, operator always knows when the special attention is needed and can eliminate risk of results variability problem with difficult patients.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h4>ANALYSIS, PROGRESSION<\/h4>\n<div>\n<div>\n<div>\n<p>PTS 920 offers complete palette of analysis tools for quick and thorough assessment of visual fields. Advanced analysis algorithms supported by normative and statistical data help in comprehensive identification of defects. Comparison and progression module available in standard package help to gain advantage in long term results evaluation.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h4>EXAMPLES OF THE TEST RESULTS<\/h4>\n<div class=\"tab-content show-content\">\n<div class=\"container\">\n<div class=\"text-section\">\n<p><a href=\"http:\/\/www.optopol.com\/public\/userfiles\/skany nowe\/1p920.jpg\"><img fetchpriority=\"high\" decoding=\"async\" class=\"alignright\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/skany nowe\/1p920.jpg\" alt=\"\" width=\"375\" height=\"531\" \/><\/a>\u00a0 \u00a0<a href=\"http:\/\/www.optopol.com\/public\/userfiles\/skany nowe\/3p920.jpg\"><img decoding=\"async\" class=\"alignleft\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/skany nowe\/3p920.jpg\" alt=\"\" width=\"374\" height=\"529\" \/><\/a><\/p>\n<p><strong>SOFTWARE<\/strong><\/p>\n<p><strong><a href=\"http:\/\/www.optopol.com\/public\/userfiles\/skany\/ex1.png\" target=\"_blank\" rel=\"noopener noreferrer\"><img decoding=\"async\" class=\"alignnone\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/skany\/ex1.png\" alt=\"\" width=\"188\" height=\"129\" \/><\/a><a href=\"http:\/\/www.optopol.com\/public\/userfiles\/skany\/ex_2.png\" target=\"_blank\" rel=\"noopener noreferrer\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/skany\/ex_2.png\" alt=\"\" width=\"189\" height=\"129\" \/><\/a><a href=\"http:\/\/www.optopol.com\/public\/userfiles\/skany\/ex3.png\" target=\"_blank\" rel=\"noopener noreferrer\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/skany\/ex3.png\" alt=\"\" width=\"191\" height=\"130\" \/><\/a><a href=\"http:\/\/www.optopol.com\/public\/userfiles\/skany nowe\/4n920.png\" target=\"_blank\" rel=\"noopener noreferrer\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/skany nowe\/4n920.png\" alt=\"\" width=\"191\" height=\"131\" \/><\/a><\/strong><br \/>\n<strong><em>* &#8211; PTS 920BY<\/em><\/strong><\/p>\n<\/div>\n<\/div>\n<\/div>\n<div><\/div>\n<h3>Technical Specifications<\/h3>\n<div>\n<table>\n<tbody>\n<tr>\n<td><strong>Examination bowl<br \/>\n<\/strong><\/td>\n<td>300 mm radius, closed type, ventilated<\/td>\n<\/tr>\n<tr>\n<td><strong>Tested field range<\/strong><\/td>\n<td>100 \u00b0 (160 with fixation shift horizontally)<\/td>\n<\/tr>\n<tr>\n<td><strong>Perimetry technique<\/strong><\/td>\n<td>Static<\/td>\n<\/tr>\n<tr>\n<td><strong>Stimulus size<\/strong><\/td>\n<td>Goldman III<\/td>\n<\/tr>\n<tr>\n<td><strong>Stimulus colors<\/strong><\/td>\n<td>blue*, green<\/td>\n<\/tr>\n<tr>\n<td><strong>Maximum stimulus intensity<\/strong><\/td>\n<td>1000 asb<\/td>\n<\/tr>\n<tr>\n<td><strong>Fixation control<\/strong><\/td>\n<td>Gaze tracking, Blink Monitoring,\u00a0 Heijl\/Krakau blind spot monitoring<\/td>\n<\/tr>\n<tr>\n<td><strong>Patient response time<\/strong><\/td>\n<td>adaptive to patient speed or set manually from 0,1 to 9,9 s<\/td>\n<\/tr>\n<tr>\n<td><strong>Background illumination<\/strong><\/td>\n<td>10 asb for green stimuli,<br \/>\n314 asb yellow background for blue stimuli<\/td>\n<\/tr>\n<tr>\n<td><strong>Test fields<\/strong><\/td>\n<td>C-24A \u2013 Central (24\u00b0 with extent to 30\u00b0nasally)<br \/>\nC-30A &#8211; Central(30\u00b0)<br \/>\nF-50 &#8211; Full (50\u00b0 in all directions)<br \/>\nC-22 &#8211; Central (30\u00b0 in horizontal axis and 22\u00b0 in vertical axis)<br \/>\nG-50 &#8211; Glaucoma (30\u00b0 with extent up to 50\u00b0 in nasal direction)<br \/>\nP-50 &#8211; Peripheral (from 30\u00b0 to 50\u00b0)<br \/>\nM-10 &#8211; Macula (up to 10\u00b0)<br \/>\nE-80 \u2013 Extended (special field for drivers examination \u2013 50\u00b0 in nasal direction, 80\u00b0 in temporal direction),<br \/>\nC-30 &#8211; Fast (up to 30\u00b0 with scarce points)<br \/>\nBDT\u2013 Binocular Driving Test (160\u00b0 bitemporal, 100\u00b0 vertical)<br \/>\nUser (up to 50\u00b0 user defined)<\/td>\n<\/tr>\n<tr>\n<td><strong>Strategies<\/strong><\/td>\n<td>Threshold, Fast threshold, Advanced Threshold,\u00a0 Screening,<br \/>\n3-zone, 2-zone, BSV (Binocular Single Vision),<br \/>\nFlicker (Critical Fusion Frequency),<br \/>\nBDT (Binocular Driving Test)<\/td>\n<\/tr>\n<tr>\n<td><strong>Result maps<\/strong><\/td>\n<td>Hill of Vision Deviation, Total Deviation (Age norm), Pattern Deviation, Total Deviation Probability, Pattern Deviation Probability, Defects Progress Analysis, Results Comparison, Bebie Curve, Pupil Movement Graph, 3D Visualization of Patients HOV<\/td>\n<\/tr>\n<tr>\n<td><strong>Connectivity<\/strong><\/td>\n<td>DICOM Storage SCU, DICOM MWL SCU, GDT, Text files, Command line<\/td>\n<\/tr>\n<tr>\n<td><strong>Device interface<\/strong><\/td>\n<td>USB 2.0<\/td>\n<\/tr>\n<tr>\n<td><strong>Dimensions (HxWxD)<\/strong><\/td>\n<td>645 x 561 x 385 , 11kg<\/td>\n<\/tr>\n<tr>\n<td><strong>Operating Voltage<\/strong><\/td>\n<td>100-120VAC 50-60Hz or 220-240V AC 50Hz<\/td>\n<\/tr>\n<tr>\n<td><strong><em>* &#8211; PTS 920BY<\/em><\/strong><\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<h4><a href=\"http:\/\/visioncare.biz\/Backup\/Files\/pts-09-2018-rev-2-online-version.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><span style=\"color: #000080;\"><strong>PTS-920 &amp; 920BY Brochure<\/strong><\/span><\/a><\/h4>\n<div><\/div>\n<div><\/div>\n","protected":false},"excerpt":{"rendered":"<h3 class=\"details-lead-text\">Fast and precise perimetry at your fingertips.<\/h3>\n<h6 class=\"details-intro-text\">Automated Perimeter PTS 920 is a modern diagnostic instrument for precise and fast testing of field of vision. Beside standard perimetry testing techniques it implements all modern approaches which save time and deliver cutting edge precision and reliability. Intuitive software with powerful networking and EMR integration, combined with maintenance free and reliable hardware creates the best tool for visual field testing.<\/h6>\n","protected":false},"featured_media":918,"comment_status":"open","ping_status":"closed","template":"","meta":{"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"product_cat":[17],"product_tag":[],"class_list":["post-865","product","type-product","status-publish","has-post-thumbnail","product_cat-uncategorized","first","instock","shipping-taxable","product-type-simple","entry","content-bg","loop-entry"],"_links":{"self":[{"href":"https:\/\/visioncare.biz\/index.php?rest_route=\/wp\/v2\/product\/865","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/visioncare.biz\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/visioncare.biz\/index.php?rest_route=\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/visioncare.biz\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=865"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/visioncare.biz\/index.php?rest_route=\/wp\/v2\/media\/918"}],"wp:attachment":[{"href":"https:\/\/visioncare.biz\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=865"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/visioncare.biz\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=865"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/visioncare.biz\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=865"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}