{"id":1436,"date":"2023-12-01T11:05:37","date_gmt":"2023-12-01T11:05:37","guid":{"rendered":"https:\/\/visioncare.biz\/wp\/?post_type=product&#038;p=1436"},"modified":"2023-12-01T11:06:15","modified_gmt":"2023-12-01T11:06:15","slug":"optopol-revo-nx-130","status":"publish","type":"product","link":"https:\/\/visioncare.biz\/?product=optopol-revo-nx-130","title":{"rendered":"OPTOPOL REVO NX 130"},"content":{"rendered":"<h5>New OCT standard &#8211; All functionality In One device.<\/h5>\n<p>Once again Revo NX goes beyond the limits of standard OCT. With its new scanning speed, our Revo NX 130 enables a full functionality scanning from the retina to the cornea. It brings benefits by combining the potential of several devices. With REVO you can measure, quantify, calculate and track changes from the cornea to the retina over time with just one OCT device.<\/p>\n<h5>i Tracking\u2122<\/h5>\n<p>iTracking\u2122 technology compensates involuntary eye movements and blinks. When OCT scan is used each anatomical region is acquired twice automatically. The system immediately creates an artifactfree MC examination using the Motion Correction TechnologyTM. The elimination of eye movement and blinking artifacts ensures the highest resolution of Angio OCT images without patient inconvenience. Clear OCTA data set allows easier interpret retina vasculature condition.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX%20130\/iTrackingTM%20rev2.png\" width=\"367\" height=\"227\" \/><\/p>\n<h5>RETINA<\/h5>\n<p>Single 3D Retina examination is enough to perform both Retina and Glaucoma analysis based on retinal scans. Software automatically recognize 8 \u00a0retina layers. Thus allowing a more precise diagnosis and mapping any changes in the patient\u2019s retina condition.<\/p>\n<p style=\"text-align: left;\">Single\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0Both<\/p>\n<p><img decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_03_2019\/RETINA%20Single%20View.PNG\" width=\"250\" height=\"156\" \/>\u00a0 <img decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_03_2019\/RETINA%20Both%20View.PNG\" width=\"247\" height=\"154\" \/><\/p>\n<p>Comparison\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Progression<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_03_2019\/RETINA%203D%20COMPARISSON.PNG\" width=\"247\" height=\"154\" \/>\u00a0 <img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_03_2019\/RETINA%203D%20PROGRESSION.PNG\" width=\"246\" height=\"153\" \/><\/p>\n<h5>OCT Angiography<\/h5>\n<p>This optional software module allows visualization of the retinal microvasculature. Angiography SOCT is a non-invasive, dye-free technique providing 3D image of retinal blood circulation.<br \/>\nSoftware allows to observe, track and compare changes in the microvasculature of the retina in both eyes.<\/p>\n<p>Standard Single View\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0Detailed Single View<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/ANGIOGRAPHY%20OCT%20Standard%20Single%20View.png\" alt=\"OCT Angiography Standard Single View \" width=\"278\" height=\"174\" \/>\u00a0 \u00a0 <img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20FC\/Detailed%20Single%20detaild%20DENSITY%20%20view%202019%2008%2008.PNG\" alt=\"OCT Angiography Detailed Single View\" width=\"279\" height=\"174\" \/><\/p>\n<p>Both View<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/ANGIOGRAPHY%20OCT%20Both%20eyes%20Retina%20Angio%20view.png\" alt=\"OCT Angiography Both View\" width=\"282\" height=\"176\" \/><\/p>\n<p>Comparison View\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Progression View<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/ANGIOGRAPHY%20OCT%20Comparison%20Retina%20Angio%20view.png\" alt=\"OCT Angiography Comparison View\" width=\"284\" height=\"178\" \/>\u00a0 <img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/ANGIOGRAPHY%20OCT%20Progression%20Retina%20Angio%20view.png\" alt=\"OCT Angiography Progression View\" width=\"286\" height=\"180\" \/><\/p>\n<h5>ANGIO ANALYISIS METHODS<\/h5>\n<h5>QUANTIFICATION<\/h5>\n<p>The quantification tool provides quantification of the vasculature in the whole analyzed area together with values in specific zones and sectors. Thanks to the heat map of the analyzed vasculature the evaluation of vascular structure conditions is much faster. The choice of the quantification method increases the sensitivity of analyses for specific deseases.<\/p>\n<p>Available quantification methods:<\/p>\n<ul>\n<li>Vessel Area Density &#8211; it is defined as the total area of perfused vasculature per unit area in a region of measurement.<\/li>\n<li>Skeleton Area Density &#8211; it is defined as the total area of skeletonized vasculature per unit area in a region of measurement.<\/li>\n<\/ul>\n<p>Quantification is available for a specific layer in Angio OCT exam:<\/p>\n<ul>\n<li>Retina: Superficial Plexus and Deep Plexus<\/li>\n<li>Disc: RPC &#8211; Radial Peripapillary Capillary<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX%20130\/Quantification%20Skeleton%20Density%20Map.png\" alt=\"Quantification Skeleton Density Map\" width=\"167\" height=\"163\" \/>\u00a0 \u00a0 <img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX%20130\/Quantification%20Vessel%20Density%20Map.png\" alt=\"Quantification Vessel Density Map\" width=\"164\" height=\"160\" \/><\/p>\n<p>Skeleton Density Map\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Vessel Density Map<\/p>\n<h5>ANGIO-ANALYTICAL TOOLS<\/h5>\n<p>FAZ \u2013 Foveal Avascular Zone measurements enable the quantification and monitoring of changes in Superficial and Deep vascular layers. The FAZ tool is also available for narrow and wide scans.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/ANGIOGRAPHY%20OCT%20FAZ%201.png\" alt=\"OCT Angiography FAZ \u2013 Foveal Avascular Zone \" width=\"213\" height=\"213\" \/>\u00a0 \u00a0 <img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/ANGIOGRAPHY%20OCT%20FAZ%202.PNG\" alt=\"OCT Angiography FAZ \u2013 Foveal Avascular Zone \" width=\"210\" height=\"211\" \/><\/p>\n<p style=\"padding-left: 320px; text-align: left;\">FAZ Area [mm2]<br \/>\nPerimeter [mm]<br \/>\nCircularity<\/p>\n<p>VFA \u2013 Vascular Flow Area allows the user to examine the pathologically affected area and to precisely measure the area covered by vascularization.<br \/>\nThe simple and easy area measurement can be performed on a predefined or user-selected vascular layer.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/ANGIOGRAPHY%20OCT%20VFA%201.png\" alt=\"OCT Angiography VFA \u2013 Vascular Flow Area\" width=\"210\" height=\"211\" \/>\u00a0 <img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/ANGIOGRAPHY%20OCT%20VFA%202.png\" alt=\"OCT Angiography VFA \u2013 Vascular Flow Area\" width=\"210\" height=\"210\" \/><\/p>\n<p style=\"padding-left: 320px;\">Area [mm2]<br \/>\nFlow Area [mm2]<\/p>\n<p>NFA \u2013 Non Flow Area measurement tool makes it possible to quantify the Non Flow Area on the OCT Angio examination. It provides the sum of all marked areas.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX%20130\/OCT%20Angiography%20NFA.png\" alt=\"OCT Angiography NFA\" width=\"219\" height=\"218\" \/>\u00a0 <img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX%20130\/OCT%20Angiography%20NFA%202.png\" alt=\"OCT Angiography NFA\" width=\"218\" height=\"216\" \/><\/p>\n<p style=\"text-align: left; padding-left: 280px;\">Non Flow Area [mm2]<\/p>\n<h5 style=\"text-align: left;\">ANGIO MOSAIC<\/h5>\n<p style=\"text-align: left;\">The Angiography mosaic delivers high-detailed images over large field of the retina.<br \/>\nAdvanced tab provides: view of any vascular layers, enface view of vascular layers, depth coded and thickness map. Mosaic modes: 10&#215;6 mm, 12&#215;5 mm, 7&#215;7 mm, 10&#215;10 mm and Manual (up to 12 images).<\/p>\n<table style=\"height: 368px;\" width=\"601\">\n<tbody>\n<tr>\n<td width=\"198\">Mosaic modes: 10&#215;10 mm<\/p>\n<p><img decoding=\"async\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_05_2017\/angio%20mosaic%2010x10.png\" \/><\/td>\n<td width=\"227\">\u00a0Mosaic modes: 7&#215;7 mm<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_05_2017\/angio%20mosaic%207x7.png\" width=\"280\" height=\"174\" \/><\/td>\n<\/tr>\n<tr>\n<td width=\"198\">Mosaic modes: 10&#215;6 mm<\/p>\n<p><img decoding=\"async\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO_05_2017\/angio%20mosaic%2010x6.PNG\" \/><\/td>\n<td width=\"227\">\u00a0Manual (up to 12 images)<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_05_2017\/angio%20mosaic%20manual%20mode%20NX.png\" width=\"268\" height=\"168\" \/><\/td>\n<\/tr>\n<tr>\n<td width=\"198\">Mosaic modes: 12&#215;5 mm<\/p>\n<p><img decoding=\"async\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_05_2017\/angio%20mosaic%2012x5%20seperficial%20maps.PNG\" \/><\/td>\n<td width=\"227\">\u00a0Mosaic modes: 12&#215;5 mm &#8211; RPC Enface view<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_05_2017\/angio%20mosaic%2012x5%20enface%20RPC%20mapsv3.PNG\" width=\"276\" height=\"171\" \/><\/td>\n<\/tr>\n<tr>\n<td width=\"198\">Mosaic modes: 12&#215;5 mm &#8211;<br \/>\nNFL Thickness map<img decoding=\"async\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_05_2017\/angio%20mosaic%2012x5%20NFL%20thickness%20maps.PNG\" \/><\/td>\n<td width=\"227\">Mosaic modes: 12&#215;5 mm &#8211;<br \/>\nRetina Thickness map<img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_05_2017\/angio%20mosaic%2012x5%20retina%20thickness%20maps.PNG\" width=\"276\" height=\"171\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h5><\/h5>\n<h5>GLAUCOMA<\/h5>\n<p>Comprehensive glaucoma analytical tools for quanti\ufb01cation of the Nerve Fiber Layer, Ganglion layer and Optic Head with DDLS allow for the precise diagnosis and monitoring of glaucoma over time.<br \/>\nWith the golden standard 14 optic nerve parameters and a new Rim to Disc and Rim Absence the description of ONH condition is quick and precise.<br \/>\nAdvanced view which provides combined information from Retina and Disc scan to integrate details of the Ganglion cells, RNFL, ONH in a wide field perspective for comprehensive analysis.<\/p>\n<p>Advance Retina &amp; ONH\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0ONH Single<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/GLAUCOMA%20Advance%20Retina%20%26%20ONH.png\" alt=\"GLAUCOMA Advance Retina &amp; ONH\" width=\"264\" height=\"166\" \/>\u00a0 <img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/GLAUCOMA%20ONH%20Single.png\" alt=\"GLAUCOMA ONH Single\" width=\"267\" height=\"167\" \/><br \/>\nAsymmetry Analysis of Ganglion layers between hemi-spheres and between eyes allows easier identification and detection of glaucoma in early stages and in non-typical patients.<\/p>\n<p>Ganglion Both\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Ganglion Progression<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/GLAUCOMA%20Ganglion%20Both.png\" alt=\"GLAUCOMA Ganglion Both\" width=\"269\" height=\"168\" \/>\u00a0 \u00a0 <img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/GLAUCOMA%20Ganglion%20Progression.png\" alt=\"GLAUCOMA Ganglion Progression\" width=\"270\" height=\"170\" \/><\/p>\n<p>Implemented the DDLS\u00a0 &#8211; Disc Damage Likelihood Scale which use 3 separate classification for small, average and large discs. It supports the practitioners in a quick and precise evaluation of the patient\u2019s glaucomatous disc damages.<\/p>\n<p>ONH Both\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0ONH Progression<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/GLAUCOMA%20ONH%20Both.png\" alt=\"GLAUCOMA ONH Both\" width=\"265\" height=\"166\" \/>\u00a0 \u00a0 <img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/GLAUCOMA%20ONH%20Progression.png\" alt=\"GLAUCOMA ONH Progression\" width=\"265\" height=\"167\" \/><\/p>\n<h5>COMPLETE YOUR GLAUCOMA REPORT<\/h5>\n<p>To eliminate common problem with the understanding of the patient\u2019s IOP pachymetry module provides IOP Correction value.\u00a0 With the implemented Adjusted IOP formula you can quickly and precisely understand the measured IOP value.<br \/>\nAs the Pachymetry and Anterior Chamber Angle Verification require no additional attachments, the predefined Glaucoma protocol, which consists of Retina, Disc and Anterior scans, can be done automatically to reduce patient chair time.<\/p>\n<p>Closing angle\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0Anterior single view<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/GLAUCOMA%20Closing%20angle.png\" alt=\"Closing angle\" width=\"286\" height=\"178\" \/>\u00a0 <img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/GLAUCOMA%20Anterior%20single%20view.png\" alt=\"Anterior single view\" width=\"287\" height=\"179\" \/><\/p>\n<p>* Images courtesy of Prof. Edward Wyl\u0119ga\u0142a MD, PhD<\/p>\n<h5>COMPREHENSIVE GLAUCOMA SOLUTION<\/h5>\n<h5>STRUCTURE &amp; FUNCTION &#8211; Combined OCT and VF results analysis<\/h5>\n<p>Invaluable combination of information about the functional quality of vision with comprehensive data on retinal Ganglion Cells, RNFL and Optic Nerve Head for both eyes on a single report page. The S&amp;F report contains the following:<\/p>\n<ul>\n<li>VF sensitivity results (24-2\/30-2 or 10-2)<\/li>\n<li>Total and Pattern Deviation probability graphs for VF results<\/li>\n<li>Reliability and Global indices for VF results<\/li>\n<li>Combined map of Structure &amp; Function<\/li>\n<li>Ganglion cell analysis (GCL+IPL or NFL+GCL+IPL)<\/li>\n<li>ONH and NFL analysis including charts and comparison tables<\/li>\n<li>NFL Asymmetry Plot<\/li>\n<\/ul>\n<p>The S&amp;F report compares in a natural way the anatomical relationship between VF and RNFL\/Ganglion maps.<br \/>\nStructure &amp; Function<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX%20130\/STRUCTURE%20%26%20FUNCTION%20-%20Combined%20OCT%20and%20VF%20results%20analysis.png\" alt=\"STRUCTURE &amp; FUNCTION - Combined OCT and VF results analysis\" width=\"281\" height=\"176\" \/><\/p>\n<h5>SINGLE PAGE REPORT<\/h5>\n<p>S+F provides a quick and comprehensive single page report for glaucoma management.<\/p>\n<h5>ANTERIOR<\/h5>\n<p>For standard examinations no additional lens is required. \u00a0Additional adapter provided with the device allows to make wide scans of anterior segment.<\/p>\n<p>Cornea single\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0Cornea both<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/anterior%20analysis.png\" alt=\"ANTERIOR Cornea single \" width=\"295\" height=\"188\" \/>\u00a0 \u00a0 <img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_03_2019\/ANTERIOR%20cornea%20both.PNG\" alt=\"ANTERIOR Cornea both\" width=\"283\" height=\"175\" \/><\/p>\n<p>Cornea Comparison\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0Cornea Progression<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/ANTERIOR%20Cornea%20Comparison.PNG\" alt=\"Anterior Cornea Comparison\" width=\"289\" height=\"180\" \/>\u00a0 \u00a0 <img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/ANTERIOR%20Cornea%20progression.PNG\" alt=\"Anterior Cornea Progression\" width=\"291\" height=\"182\" \/><\/p>\n<p>&nbsp;<\/p>\n<h5>BIOMETRY OCT is optional software module to purchase<\/h5>\n<p>B-OCT\u2122 innovative method of using the\u00a0 posterior OCT device to measure ocular structure along eye axis .<br \/>\nOCT Biometry provides complete set of Biometry parameters: Axial Length\u00a0AL, Central Cornea Thickness\u00a0CCT, Anterior Chamber Depth\u00a0ACD, Lens Thickness\u00a0LT.<\/p>\n<p>Result review\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Analysis window<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_03_2019\/BIOMETRY%20OCT%20Result%20review.PNG\" width=\"267\" height=\"165\" \/>\u00a0 \u00a0 \u00a0 <img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_03_2019\/BIOMETRY%20OCT%20Analysis%20window.PNG\" width=\"260\" height=\"166\" \/><\/p>\n<p>Visually verify your measurement<br \/>\nAll measurement calipers are shown on the all boundaries OCT image provided by REVO. Now, you can visually verify and correct what structure of the eye has been measured.<\/p>\n<h5>TOPOGRAPHY OCT is optional software module to purchase<\/h5>\n<p>T-OCT\u2122 is a pioneering way to provide detailed corneal Curvature maps by using posterior dedicated OCT. Ante-rior, Posterior\u00a0 surface and Corneal Thickness allow to provide the\u00a0 True Net Curvature information. With Net power, the precise understading of the patient\u2019s corneal condition comes easily and is free of errors associated with modelling of posterior surface of the cornea.\u00a0 SOCT T-OCT module provides Axial maps, Tangential maps, Total Power map, Height maps, Epithelium and Corneal thickness maps.<br \/>\nCorneal topography module clearly shows the changes in the cornea on the difference map view. Customize your<br \/>\nTopography module provides:<\/p>\n<ul>\n<li>Full featured Corneal mapping of Anterior, Posterior and Real<\/li>\n<li>Precise Astigmatism Display Option (SimK: Anterior, Posterior, Real,\u00a0 Meridian and Emi-Meridian \u00f8 3, 5, 7 mm zones<\/li>\n<\/ul>\n<h5>KERATOCONUS SCREENING<\/h5>\n<p>Easly detect and classified keratoconus with Keratoconus classifier. Classification based on KPI, SAI, DSI, OSI and CSI. In the early stages of kera-toconus the results can be complemented by Epithelium and Pachymatery maps.<\/p>\n<table border=\"0\" cellspacing=\"1\" cellpadding=\"1\">\n<tbody>\n<tr>\n<td>Normal<\/td>\n<td>Astigmatysm<\/td>\n<td>Keratoconus<\/td>\n<\/tr>\n<tr>\n<td><a href=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/TOPOGRAPHY%20normal.PNG\"><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/TOPOGRAPHY%20normal.PNG\" alt=\"KERATOCONUS SCREENING\" width=\"172\" height=\"154\" \/><\/a><\/td>\n<td><a href=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/TOPOGRAPHY%20astigmatism.PNG\"><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/TOPOGRAPHY%20astigmatism.PNG\" alt=\"KERATOCONUS SCREENING\" width=\"177\" height=\"158\" \/><\/a><\/td>\n<td><a href=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/TOPOGRAPHY%20keratoconus.png\"><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/TOPOGRAPHY%20keratoconus.png\" alt=\"KERATOCONUS SCREENING\" width=\"178\" height=\"161\" \/><\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h5>COMPARE THE EXAMS<\/h5>\n<p>Comprehensive software features\u00a0 a range of selectable views: Single, Both. See details on standard Singe view and easly see corneal asymmetry on the Both view.<br \/>\nThe follow-up feature in to the T-OCT\u2122 module, allows fully compare the changes in the corneal topography over time for:<\/p>\n<ul>\n<li>LASIK undergone patients<\/li>\n<li>Keratoconus patients<\/li>\n<li>The contact lens wearers<\/li>\n<\/ul>\n<p>Single\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Both<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/TOPOGRAPHY%20single.png\" alt=\"TOPOGRAPHY OCT SINGLE\" width=\"258\" height=\"162\" \/>\u00a0 <img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/TOPOGRAPHY%20both.png\" alt=\"TOPOGRAPHY OCT BOTH\" width=\"259\" height=\"162\" \/><\/p>\n<p>Comparisonc\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Progression<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/TOPOGRAPHY%20comparison.PNG\" alt=\"TOPOGRAPHY OCT COMPARISON\" width=\"249\" height=\"155\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/TOPOGRAPHY%20%20progression.PNG\" alt=\"TOPOGRAPHY OCT PROGRESSION\" width=\"247\" height=\"154\" \/><\/p>\n<h5>FOLLOW UP<\/h5>\n<p>High density of standard 3D scan allows to precisely track the disease progress.\u00a0Operator can analyze changes is morphology,\u00a0 quantified progression maps or evaluate the progression trends.<br \/>\nProgression Morphology\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Progression Quantification<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/FOLLOW%20UP%20Progression%20Morphology.png\" alt=\"FOLLOW UP Progression Morphology \" width=\"253\" height=\"158\" \/>\u00a0 <img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/FOLLOW%20UP%20Progression%20Quantification.png\" alt=\"FOLLOW UP Progression Quantification\" width=\"258\" height=\"161\" \/><\/p>\n<h5>COMPARISON<\/h5>\n<p>Comparison view allows in easy and convince way to review results from two visits. The view is available for most of the scan programs.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO_05_2017\/COMPARISON.png\" width=\"298\" height=\"187\" \/><\/p>\n<h5>NETWORKING<\/h5>\n<p>A proficient networking solution increases productivity and an enhanced patient experience. It allows you to view and manipulate multiple examinations from review stations in your practice. Effortlessly helping to facilitate patient education by allowing you to interactively show examination results to patients. Every practice will have differing requirements which we can provide by tailoring a bespoke service. There is no additional charge for the server module.<\/p>\n<h5>DICOM<\/h5>\n<p>Store, exchange, and transmit results through DICOM gateway to the hospital network.<\/p>\n<table style=\"height: 24px;\" border=\"0\" width=\"638\" cellspacing=\"1\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td><strong>CNV\u00a0 \u00a0\u00a0<\/strong><\/td>\n<td><strong>BRVO<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong><a href=\"http:\/\/www.optopol.com\/public\/userfiles\/CNV.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/CNV.png\" alt=\"\" width=\"319\" height=\"200\" \/><\/a>\u00a0<a href=\"http:\/\/www.optopol.com\/public\/userfiles\/BRV.png\"><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/BRV.png\" alt=\"\" width=\"320\" height=\"201\" \/><\/a><\/strong><\/p>\n<p><strong>ENHANCE TOMOGRAMS &#8211; 2 \u00b5m Ultra High (Digital) Resolution<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/ENHANCE%20TOMOGRAMS%20-%202%20%C2%B5m%20Ultra%20High%20Digital%20%20Resolution.png\" width=\"319\" height=\"196\" \/><\/p>\n<p><strong>CHOROID VISUALIZATION<\/strong><strong><br \/>\n<\/strong><\/p>\n<p><strong><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_05_2017\/CHOROID%20VISUALIZATION.png\" width=\"282\" height=\"125\" \/>\u00a0 \u00a0 <img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_05_2017\/CLINICAL%20IMAGES%207.png\" width=\"205\" height=\"122\" \/><\/strong><\/p>\n<p>&nbsp;<\/p>\n<p><strong>CLINIC IMAGES<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_05_2017\/CLINICAL%20IMAGES%201.png\" width=\"276\" height=\"161\" \/>\u00a0 <img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_05_2017\/CLINICAL%20IMAGES%202.png\" alt=\"\" width=\"269\" height=\"116\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_05_2017\/CLINICAL%20IMAGES%203.png\" width=\"276\" height=\"164\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_05_2017\/CLINICAL%20IMAGES%204.png\" width=\"274\" height=\"163\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_05_2017\/CLINICAL%20IMAGES%206.png\" width=\"279\" height=\"124\" \/><\/p>\n<p><strong>CORNEA SCAN<\/strong><br \/>\n<strong><a href=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_05_2017\/CLINICAL%20IMAGES%208.png\"><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_05_2017\/CLINICAL%20IMAGES%208.png\" alt=\"\" width=\"314\" height=\"90\" \/><\/a>\u00a0<a href=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_05_2017\/CLINICAL%20IMAGES%209.png\"><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_05_2017\/CLINICAL%20IMAGES%209.png\" alt=\"\" width=\"315\" height=\"90\" \/><\/a><br \/>\nWide cornea scan, Descemet\u2019s membrane detachment (DMD) and iridocorneal adhesions<\/strong><br \/>\n<a href=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/WIDE%20CORNEA%20SCAN.png\"><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/WIDE%20CORNEA%20SCAN.png\" alt=\"Wide cornea scan, Descemet\u2019s membrane detachment (DMD) and iridocorneal adhesions\" width=\"636\" height=\"204\" \/><\/a><br \/>\n<sup>* Images courtesy of Prof. Edward Wyl\u0119ga\u0142a MD, PhD<\/sup><\/p>\n<p><strong>ANTERIOR<br \/>\n<a href=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_05_2017\/ANTERIOR.png\"><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_05_2017\/ANTERIOR.png\" alt=\"\" width=\"330\" height=\"174\" \/><\/a><br \/>\nAnterior scan, Cornea Guttata with corneal scaring<br \/>\n<a href=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/ANTERIOR%20scan.png\"><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/ANTERIOR%20scan.png\" alt=\"Anterior scan, Cornea Guttata with corneal scaring\" width=\"699\" height=\"224\" \/><\/a><\/strong><\/p>\n<p>&nbsp;<\/p>\n<p><strong>ANGIOGRAPHY<\/strong><\/p>\n<table border=\"0\" cellspacing=\"1\" cellpadding=\"1\">\n<tbody>\n<tr>\n<td><a href=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_03_2019\/ANGIOGRAPHY%201.png\"><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_03_2019\/ANGIOGRAPHY%201.png\" alt=\"\" width=\"211\" height=\"211\" \/><\/a><\/td>\n<td><sub>\u00a0<\/sub>\u00a0<a href=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_03_2019\/ANGIOGRAPHY%202.png\"><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_03_2019\/ANGIOGRAPHY%202.png\" alt=\"\" width=\"214\" height=\"214\" \/><\/a><\/td>\n<\/tr>\n<tr>\n<td><a href=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_03_2019\/ANGIOGRAPHY%203.png\"><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_03_2019\/ANGIOGRAPHY%203.png\" alt=\"\" width=\"210\" height=\"210\" \/><\/a><\/td>\n<td><sub>\u00a0<\/sub><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>PDR,\u00a0 Angio Mosaic mode: 10&#215;10 mm<\/strong><br \/>\n<a href=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/PDR%20%20Angio%20Mosaic%20mode%2010x10%20mm.png\"><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/PDR%20%20Angio%20Mosaic%20mode%2010x10%20mm.png\" alt=\"PDR, Angio Mosaic mode 10x10 mm\" width=\"458\" height=\"458\" \/><\/a><br \/>\n<sup>*Images courtesy of Bartosz L. Sikorski MD, PhD<\/sup><\/p>\n<p><strong>ANGLE TO ANGLE ANALYSIS<br \/>\n<a href=\"http:\/\/www.optopol.com\/public\/userfiles\/revo\/r10.png\"><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/revo\/r10.png\" alt=\"\" width=\"656\" height=\"261\" \/><\/a><\/strong><br \/>\n<strong>Angle to Angle scan, narrow angles<\/strong><br \/>\n<a href=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/Angle%20to%20Angle%20scan%20narrow%20angles.png\"><img loading=\"lazy\" decoding=\"async\" class=\"\" src=\"http:\/\/www.optopol.com\/public\/userfiles\/REVO%20NX_01_2019\/Angle%20to%20Angle%20scan%20narrow%20angles.png\" alt=\"Angle to Angle scan, narrow angles\" width=\"671\" height=\"176\" \/><\/a><br \/>\n<sup>*Image courtesy of Bartosz L. Sikorski MD, PhD<\/sup><\/p>\n<p>&nbsp;<\/p>\n<h4>Technical Specification<\/h4>\n<table style=\"height: 1698px;\" width=\"761\">\n<tbody>\n<tr>\n<td><strong>Technology<\/strong><\/td>\n<td style=\"text-align: right;\">Spectral Domain OCT<\/td>\n<\/tr>\n<tr>\n<td><strong>Scanning speed<\/strong><\/td>\n<td style=\"text-align: right;\">130\u00a0000 A-scan\/sec<\/td>\n<\/tr>\n<tr>\n<td><strong>Light Source<\/strong><\/td>\n<td style=\"text-align: right;\">SLED, Wavelength 830nm<\/td>\n<\/tr>\n<tr>\n<td><strong>Bandwidth<\/strong><\/td>\n<td style=\"text-align: right;\">50 nm half bandwidth<\/td>\n<\/tr>\n<tr>\n<td><strong>Axial resolution<\/strong><\/td>\n<td style=\"text-align: right;\">~2,6 \u03bcm\u00a0digital, 5 \u03bcm in tissue<\/td>\n<\/tr>\n<tr>\n<td><strong>Transverse Resolution<\/strong><\/td>\n<td style=\"text-align: right;\">12 \u03bcm, typical 18 \u03bcm<\/td>\n<\/tr>\n<tr>\n<td><strong>Overall scan depth<\/strong><\/td>\n<td style=\"text-align: right;\">2.4 mm<\/td>\n<\/tr>\n<tr>\n<td><strong>Scan range<\/strong><\/td>\n<td style=\"text-align: right;\">Posterior 5 mm to 12 mm, Angio 3 mm to 9 mm, Anterior 3 mm to 16 mm<\/td>\n<\/tr>\n<tr>\n<td><strong>Scan types<\/strong><\/td>\n<td style=\"text-align: right;\">3D, Angio, Radial (HD), B-scan (HD), Raster (HD), Cross (HD), TOPO, AL, ACD<\/td>\n<\/tr>\n<tr>\n<td><strong>Fundus image<\/strong><\/td>\n<td style=\"text-align: right;\">Live Fundus Reconstruction<\/td>\n<\/tr>\n<tr>\n<td><strong>Alignment method<\/strong><\/td>\n<td style=\"text-align: right;\">Fully automatic, Automatic, Manual<\/td>\n<\/tr>\n<tr>\n<td><strong>Retina analysis<\/strong><\/td>\n<td style=\"text-align: right;\">Retina thickness, Inner Retinal thickness, Outer Retinal thickness, RNFL+GCL+IPL thickness, GCL+IPL thickness, RNFL thickness,<br \/>\nRPE deformation, MZ\/EZ-RPE thickness<\/td>\n<\/tr>\n<tr>\n<td><strong>Angiography OCT<\/strong><br \/>\n<sup>an optional software module to purchase\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 <\/sup><strong>Angiography mosaic<\/strong><\/td>\n<td style=\"text-align: right;\">Vitreous, Retina, Choroid, Superficial Plexus, RPCP, Deep Plexus, Outer Retina, Choriocapilaries, Depth Coded, SVC, DVC, ICP, DCP, Custom, Enface, FAZ, VFA, NFA, Quantification: Vessel Area Density, Skeleton Area Density, Thickness map<\/p>\n<p>Acquistion method: Auto, Manual<br \/>\nMosaic modes: 7&#215;7 mm, 10&#215;6 mm, 10&#215;10 mm, 12&#215;5 mm, manual up to 12 images<\/td>\n<\/tr>\n<tr>\n<td><strong>Glaucoma analysis<\/strong><\/td>\n<td style=\"text-align: right;\">RNFL, ONH morphology, DDLS, OU and Hemisphere asymmetry, Ganglion analysis as RNFL+GCL+IP and GCL+IPL,<br \/>\nStructure + Function<sup>via connection with PTS software version 3.4 or higher<\/sup><\/td>\n<\/tr>\n<tr>\n<td><strong>Anterior<\/strong><\/td>\n<td style=\"text-align: right;\">Pachymetry, Epithelium map, Stroma map, AIOP, Angle Assessment, AOD 500\/750, TISA 500\/750<\/td>\n<\/tr>\n<tr>\n<td><strong>Biometry OCT<\/strong><br \/>\n<sup>an optional software module to purchase<\/sup><\/td>\n<td style=\"text-align: right;\">AL, CCT, ACD, LT<\/td>\n<\/tr>\n<tr>\n<td><strong>Corneal Topography Map<\/strong><br \/>\n<sup>an optional software module to purchase<\/sup><\/td>\n<td style=\"text-align: right;\">Axial [Anterior, Posterior], Refractive Power [Kerato, Anterior, Posterior, Total], Net Map, Axial True Net, Equivalent Keratometer, Elevation [Anterior, Posterior], Height, KPI (Keratoconus Prediction Index)<\/td>\n<\/tr>\n<tr>\n<td><strong>Connectivity<\/strong><\/td>\n<td style=\"text-align: right;\">DICOM Storage SCU, DICOM MWL SCU, CMDL, Networking<\/td>\n<\/tr>\n<tr>\n<td><strong>Anterior Wide Scan<\/strong><\/td>\n<td style=\"text-align: right;\">Angle to Angle view (Adapter required), Wide Cornea<\/td>\n<\/tr>\n<tr>\n<td><strong>Min.\u00a0 pupil size<\/strong><\/td>\n<td style=\"text-align: right;\">3 mm<\/td>\n<\/tr>\n<tr>\n<td><strong>Focus adjustment range<\/strong><\/td>\n<td style=\"text-align: right;\">-25D to +25D<\/td>\n<\/tr>\n<tr>\n<td><strong>Dimensions (WxDxH)<\/strong><\/td>\n<td style=\"text-align: right;\">382 x 556 \u00d7 469 mm<\/td>\n<\/tr>\n<tr>\n<td><strong>Weight<\/strong><\/td>\n<td style=\"text-align: right;\">23 kg<\/td>\n<\/tr>\n<tr>\n<td><strong>Fixation target<\/strong><\/td>\n<td style=\"text-align: right;\">OLED display (The target shape and position can be changed),<br \/>\nExternal fixation arm<\/td>\n<\/tr>\n<tr>\n<td><strong>Power supply<\/strong><\/td>\n<td style=\"text-align: right;\">110-230 V,\u00a0 60\/50 Hz<\/td>\n<\/tr>\n<tr>\n<td><strong>Power consumption<\/strong><\/td>\n<td style=\"text-align: right;\">115 &#8211; 140 VA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h4>Download Brochure<\/h4>\n<p><a href=\"http:\/\/www.visioncare.biz\/Backup\/Files\/revonx-130.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone\" title=\"REVO NX 130 Brochure\" src=\"https:\/\/upload.wikimedia.org\/wikipedia\/commons\/8\/87\/PDF_file_icon.svg\" alt=\"File:PDF file icon.svg - Wikimedia Commons\" width=\"44\" height=\"54\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<h5 class=\"details-lead-text\">Optopol engineering team, designers of the first commercially available Spectral Domain OCT in the World, is proud to present the World\u2019s fastest OCT.<\/h5>\n<h6 class=\"details-intro-text\">Optopol engineering team, the designers of the firstcommercially available Spectral Domain OCT in the world, are proud to present the latest innovation, the world`s first B-OCT and T-OCT for standard<br \/>\nposterior OCT. Our supreme experience in Spectral Domain OCT allows us to provide the market with a state of the art instrument which comes with new advanced technologies and remarkable simplicity of operation.<\/h6>\n","protected":false},"featured_media":1481,"comment_status":"open","ping_status":"closed","template":"","meta":{"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"product_cat":[17],"product_tag":[],"class_list":["post-1436","product","type-product","status-publish","has-post-thumbnail","product_cat-uncategorized","first","instock","shipping-taxable","product-type-simple","entry","content-bg","loop-entry"],"_links":{"self":[{"href":"https:\/\/visioncare.biz\/index.php?rest_route=\/wp\/v2\/product\/1436","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/visioncare.biz\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/visioncare.biz\/index.php?rest_route=\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/visioncare.biz\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1436"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/visioncare.biz\/index.php?rest_route=\/wp\/v2\/media\/1481"}],"wp:attachment":[{"href":"https:\/\/visioncare.biz\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1436"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/visioncare.biz\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=1436"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/visioncare.biz\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=1436"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}