{"id":1005,"date":"2023-12-01T10:59:50","date_gmt":"2023-12-01T10:59:50","guid":{"rendered":"https:\/\/visioncare.biz\/wp\/?post_type=product&#038;p=1005"},"modified":"2024-09-01T05:13:35","modified_gmt":"2024-09-01T05:13:35","slug":"oculus-easygraph","status":"publish","type":"product","link":"https:\/\/visioncare.biz\/?product=oculus-easygraph","title":{"rendered":"OCULUS Easygraph"},"content":{"rendered":"<h3>Highlights<\/h3>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignleft\" src=\"https:\/\/www.oculus.de\/typo3temp\/pics\/d47ec6d52a.jpg\" alt=\"\" width=\"425\" height=\"240\" \/><\/p>\n<div class=\"produktseite_text_bild\">\n<div class=\"ps_bild_links\">\n<h4 class=\"ps_beschreibung\">The Easygraph \u2013 The Small Performance Wonder<\/h4>\n<\/div>\n<div class=\"ps_text_rechts\">\n<p>The Easygraph works with the tried and tested measuring and device technology that has become indispensable in today\u2019s contact lens fitting and reliable diagnostics fields. Ideal where space is limited.<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h4><img decoding=\"async\" class=\"alignright\" src=\"https:\/\/www.oculus.de\/fileadmin\/images\/produktbilder\/easygraph\/highlights\/easygraph_darstellung_fluobild.jpg\" alt=\"\" width=\"410\" height=\"308\" \/>Contact Lens Fitting and Fluorescein Image Simulation<\/h4>\n<div class=\"produktseite_text_bild\">\n<div class=\"ps_text_links\">\n<p>A list of recommended contact lenses available from well-known manufacturers is generated based on your patient\u2019s corneal topography data. Prior to fitting, fluorescein images can be simulated and adjusted (rotate, offset, change parameters).<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h4><img decoding=\"async\" class=\"alignleft\" src=\"https:\/\/www.oculus.de\/fileadmin\/images\/produktbilder\/easygraph\/highlights\/oculus_easygraph_oximap.jpg\" alt=\"\" width=\"410\" height=\"308\" \/>OxiMap<sup>\u00ae<\/sup>\u00a0\u2013 Visualization of the Oxygen Transmissibility of Soft Contact Lenses<\/h4>\n<div class=\"produktseite_text_bild\">\n<div class=\"ps_text_rechts\">\n<p>Easy to understand OxiMap<sup>\u00ae<\/sup>\u00a0presents a color map of the oxygen transmissibility of soft contact lenses based on the lens power, which is easy to understand \u2013 even for your customers!<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h3>Functions<\/h3>\n<div class=\"produktseite_text_bild\">\n<div class=\"ps_bild_links\">\n<div class=\"ps_bild\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft\" src=\"https:\/\/www.oculus.de\/fileadmin\/images\/produktbilder\/easygraph\/funktionen\/halterung_easygraph.jpg\" alt=\"\" width=\"200\" height=\"379\" \/><\/div>\n<h4 class=\"ps_beschreibung\">Compact Corneal Topographer<\/h4>\n<\/div>\n<div class=\"ps_text_rechts\">\n<p>The Easygraph combines small construction with grand technology. The tried and tested measuring system is identical to that of the keratograph. This compact topographer is a combination of a topography system and an integrated keratometer. In the non-contact examination process, 22\u00a0000 measuring points are used to map the cornea. Digital image transmission and automatic release guarantee the best possible reproducibility.<\/p>\n<\/div>\n<div><\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h4><img loading=\"lazy\" decoding=\"async\" class=\"alignright\" src=\"https:\/\/www.oculus.de\/fileadmin\/images\/produktbilder\/easygraph\/funktionen\/Easygraph_Funktionen_02_Aufstecken_auf_Spaltlampe.gif\" alt=\"\" width=\"388\" height=\"218\" \/>Simple Mounting on the Slit Lamp.<\/h4>\n<div class=\"produktseite_text_bild\">\n<div class=\"ps_text_links\">\n<p>The Easygraph comes complete with a slit lamp adapter and holder. These make it easy to move the Easygraph from the work position to the idle position. After using the Easygraph, you can resume the examination with the slit lamp as normal.<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<div class=\"anchor\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft\" src=\"https:\/\/www.oculus.de\/fileadmin\/images\/produktbilder\/easygraph\/funktionen\/oculus_easygraph_indizes.jpg\" alt=\"\" width=\"463\" height=\"348\" \/><\/div>\n<div class=\"produktseite_text_bild\">\n<div class=\"ps_bild_links\">\n<h4 class=\"ps_beschreibung\">Precise Measurement, Easy-to-Understand Presentation<\/h4>\n<\/div>\n<div class=\"ps_text_rechts\">\n<p>Precise measurement is the basis for many types of analysis. Graphic presentation of the data supports you in the evaluation and quantitative assessment of the corneal topography:<\/p>\n<\/div>\n<\/div>\n<div class=\"produktseite_text_bild\">\n<div class=\"ps_text_rechts\">\n<ul>\n<li>Overview with camera image and color map<\/li>\n<li>3D and 2D display<\/li>\n<li>Various color maps<\/li>\n<li>Plot of the Fourier analysis<\/li>\n<li>Refractive map<\/li>\n<li>Height map of the topography data<\/li>\n<li>Map of the sagittal and tangential radii<\/li>\n<li>Comparison of different examination results for follow-up purposes<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h4><img loading=\"lazy\" decoding=\"async\" class=\"alignright\" src=\"https:\/\/www.oculus.de\/fileadmin\/images\/produktbilder\/easygraph\/highlights\/easygraph_darstellung_fluobild.jpg\" alt=\"\" width=\"435\" height=\"327\" \/>Contact Lens Fitting<\/h4>\n<div class=\"produktseite_text_bild\">\n<div class=\"ps_text_links\">\n<p>The topography data provide the contact lens fitter with comprehensive support, whether he is a specialist or a newcomer to the job. The first placement of the contact lens and initial checking of the fit take place without any actual physical contact \u2013 simulated on the PC. This saves time and paves the way to the ideal contact lens for the patient. For hard contact lenses, a fluo-image is simulated based on the topography and the contact lens data. The contact lens can be moved with the click of a mouse, and can be rotated too for optimal fitting of toric contact lenses. After the virtual contact lens has been positioned on the real eye, the fluo-image simulation is recalculated and can be compared with realistic, static and dynamic images.<\/p>\n<\/div>\n<div class=\"ps_bild_rechts\">\n<div class=\"ps_bild\"><\/div>\n<div class=\"ps_beschreibung\"><\/div>\n<\/div>\n<\/div>\n<div class=\"produktseite_text_bild\">\n<div class=\"ps_bild_links\">\n<div class=\"ps_bild\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft\" src=\"https:\/\/www.oculus.de\/fileadmin\/images\/produktbilder\/easygraph\/funktionen\/easygraph_darstellung.jpg\" alt=\"\" width=\"410\" height=\"308\" \/><\/div>\n<div class=\"ps_beschreibung\"><\/div>\n<\/div>\n<div class=\"ps_text_rechts\">\n<h3>Progression Follow-up Diagnostics<\/h3>\n<p>Regular progression follow-ups are essential, not only for cases of keratoconus. In the &#8220;Compare examination\u201c display, up to four examinations can be directly compared with each other and any changes of the corneal topography can be displayed with color-coding.<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h4><img loading=\"lazy\" decoding=\"async\" class=\"alignright\" src=\"https:\/\/www.oculus.de\/fileadmin\/images\/produktbilder\/easygraph\/funktionen\/easygraph_darstellung_corna_astig.jpg\" alt=\"\" width=\"410\" height=\"308\" \/>Display of Refractive Corneal Changes<\/h4>\n<div class=\"produktseite_text_bild\">\n<div class=\"ps_text_links\">\n<p>Changes in the refractive power of the cornea as a resulting of wearing of Ortho-K contact lenses or of refractive surgery can be analyzed and documented.<\/p>\n<\/div>\n<div class=\"ps_bild_rechts\">\n<div class=\"ps_bild\"><\/div>\n<div class=\"ps_beschreibung\"><\/div>\n<\/div>\n<\/div>\n<div><\/div>\n<div><\/div>\n<div><\/div>\n<div><\/div>\n<h3>Additional Options<\/h3>\n<p>You can supplement the main functions of your Easygraph with various software modules customized to meet your individual requirements.<\/p>\n<p>&nbsp;<\/p>\n<h3>Technical Data<\/h3>\n<p><img decoding=\"async\" src=\"https:\/\/www.oculus.de\/fileadmin\/images\/produktbilder\/easygraph\/technische_daten\/oculus_easygraph_technische_zeichnung.jpg\" \/><\/p>\n<table class=\"contenttable contenttable-0 technischeDaten\" style=\"height: 323px;\" width=\"878\">\n<caption>Features<\/caption>\n<tbody>\n<tr class=\"tr-even tr-0\">\n<td class=\"td-0\">Measuring range<\/td>\n<td class=\"td-last td-1\">3 &#8211; 38 mm, 9 &#8211; 99 dpt<\/td>\n<\/tr>\n<tr class=\"tr-odd tr-1\">\n<td class=\"td-0\">Accuracy<\/td>\n<td class=\"td-last td-1\">\u00b1 0.1 dpt<\/td>\n<\/tr>\n<tr class=\"tr-even tr-2\">\n<td class=\"td-0\">Reproducibility<\/td>\n<td class=\"td-last td-1\">\u00b1 0.1 dpt<\/td>\n<\/tr>\n<tr class=\"tr-odd tr-3\">\n<td class=\"td-0\">Number of rings<\/td>\n<td class=\"td-last td-1\">22<\/td>\n<\/tr>\n<tr class=\"tr-even tr-4\">\n<td class=\"td-0\">Working distance<\/td>\n<td class=\"td-last td-1\">40 mm<\/td>\n<\/tr>\n<tr class=\"tr-odd tr-5\">\n<td class=\"td-0\">Number of test points<\/td>\n<td class=\"td-last td-1\">22 000<\/td>\n<\/tr>\n<tr class=\"tr-even tr-6\">\n<td class=\"td-0\">Dimensions: W x D x H<\/td>\n<td class=\"td-last td-1\">119 x 102 x 216 mm (4.7 x 4.0 x 8.5 in)<\/td>\n<\/tr>\n<tr class=\"tr-odd tr-7\">\n<td class=\"td-0\">Weight<\/td>\n<td class=\"td-last td-1\">730 g (1.6 lbs)<\/td>\n<\/tr>\n<tr class=\"tr-even tr-8\">\n<td class=\"td-0\">Power supply unit<\/td>\n<td class=\"td-last td-1\">Input: 100 &#8211; 240 V<br \/>\nOutput: 5 V \/ 1 A<\/td>\n<\/tr>\n<tr class=\"tr-odd tr-last\">\n<td class=\"td-0\">PC Minimum requirements<\/td>\n<td class=\"td-last td-1\">Processor: Intel<sup>\u00ae<\/sup>\u00a0Core\u2122\u00a0 i5-6600, 8\u00a0GB RAM, 500\u00a0GB HDD, Windows<sup>\u00ae<\/sup>\u00a010\u00a0Pro<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h3>Software<\/h3>\n<div class=\"produktseite_text_bild\">\n<div class=\"ps_bild_links\">\n<div class=\"ps_bild\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft\" src=\"https:\/\/www.oculus.de\/fileadmin\/images\/produktbilder\/easygraph\/software\/Keratokonus-Erkennungssoftware\/oculus_easygraph_indizes.jpg\" alt=\"\" width=\"410\" height=\"308\" \/><\/div>\n<h4 class=\"ps_beschreibung\">Keratoconus Detection at the Highest Level<\/h4>\n<\/div>\n<div class=\"ps_text_rechts\">\n<p>Thanks to topography measurement, corneal abnormalities can often be detected and diagnosed in the early stages. The measurements are compared with those in a norm database. If abnormalities are present, the measured values are displayed in yellow or red. If a keratoconus is present, it is classified based on the existing topography. The Topographic Keratoconus Screening also helps you in progression follow-ups and where applicable, shows you whether and how the keratoconus has changed.<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h4><img loading=\"lazy\" decoding=\"async\" class=\"alignright\" src=\"https:\/\/www.oculus.de\/fileadmin\/images\/produktbilder\/easygraph\/software\/Keratokonus-Erkennungssoftware\/oculus_easygraph_zernike.jpg\" alt=\"\" width=\"410\" height=\"308\" \/>Zernike-Analysis<\/h4>\n<div class=\"produktseite_text_bild\">\n<div class=\"ps_text_links\">\n<p>Corneal abnormalities can be displayed in 2D and 3D using the Zernike Analysis. The displayed aberration coefficient provides information about the optical image quality of the cornea. In addition to this corneal wavefront analysis, the software also marks the location of the apex and is easy for the user to recognize.<\/p>\n<\/div>\n<div class=\"ps_bild_rechts\">\n<div class=\"ps_bild\"><\/div>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h3>OCULUS OxiMap<sup>\u00ae<\/sup><\/h3>\n<p>The OxiMap<sup>\u00ae<\/sup> presents a color map of the oxygen transmissibility of soft contact lenses based on the lens power, which is easy to understand \u2013 even for your customers<img decoding=\"async\" src=\"https:\/\/www.oculus.de\/fileadmin\/images\/sonstiges\/trans_1px.jpg\" alt=\"\" \/><\/p>\n<div class=\"produktseite_text_bild\">\n<div class=\"ps_bild_links\">\n<div class=\"ps_bild\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft\" src=\"https:\/\/www.oculus.de\/fileadmin\/images\/produktbilder\/easygraph\/software\/oximap\/oculus_easygraph_oximap_sauerstoffversorgung.jpg\" alt=\"\" width=\"410\" height=\"335\" \/><\/div>\n<\/div>\n<div class=\"ps_text_rechts\">\n<h4>How Much Oxygen Really Reaches the Cornea?<\/h4>\n<p>Until now, only the oxygen transmissibility values for the center of a contact lens with -3.0 D were available. The OxiMap<sup>\u00ae\u00a0<\/sup>shows the oxygen transmissibility depending on the lens material and the lens thickness. The OxiMap<sup>\u00ae<\/sup>\u00a0is available for the most frequently sold spherical soft contact lenses. This impressive tool assists you in helping your patients select the most suitable contact lens.<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Oxygen transmissibility for a soft contact lens with the spherical power of -3.0dpt (left)\/-6.0dpt (right)<\/p>\n<div class=\"produktseite_text_bild\">\n<div><\/div>\n<\/div>\n<div class=\"produktseite_text_bild\">\n<div class=\"ps_text_links\">\n<h4><img loading=\"lazy\" decoding=\"async\" class=\"alignright\" src=\"https:\/\/www.oculus.de\/fileadmin\/images\/produktbilder\/easygraph\/software\/oximap\/oximap_graphik_aktuell.jpg\" alt=\"\" width=\"410\" height=\"308\" \/>Plain and Comprehensive Visualization Assures Patient Loyalty!<\/h4>\n<p>Contact lenses act as a potential barrier to oxygen transport even when the eyes are open to the atmosphere. Long hours of wearing comfort can only be guaranteed with a sufficient oxygen supply. The color representation of the various terms of oxygen transmissibility is based on international recommendations for daily, extended and continuous wear.<\/p>\n<\/div>\n<div class=\"ps_bild_rechts\">\n<div class=\"ps_bild\"><\/div>\n<div><\/div>\n<div class=\"ps_beschreibung\">\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0The OxiMap\u00ae color coding of the Dk\/T-values and the recommended wearing time<img decoding=\"async\" src=\"https:\/\/www.oculus.de\/fileadmin\/images\/sonstiges\/trans_1px.jpg\" alt=\"\" \/><\/div>\n<\/div>\n<\/div>\n<div class=\"anchor\"><\/div>\n<div class=\"produktseite_text_bild\">\n<div class=\"ps_bild_links\">\n<div><\/div>\n<h4 class=\"ps_beschreibung\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft\" src=\"https:\/\/www.oculus.de\/fileadmin\/images\/produktbilder\/easygraph\/software\/oximap\/oculus_keratograph_oximap_vergleich_kontaktlinsen.jpg\" alt=\"\" width=\"385\" height=\"232\" \/>Compare Different Soft Contact Lenses!<\/h4>\n<\/div>\n<div class=\"ps_text_rechts\">\n<p>The OxiMap<sup>\u00ae<\/sup>\u00a0is individually adapted based on the lens power and supports you in your consultation with the patient and helps you to choose the most suitable contact lens. New materials used for soft contact lenses provide excellent oxygen transmissibility.<\/p>\n<p>OxiMap<sup>\u00ae<\/sup>\u00a0was developed in close cooperation with JENVIS Research and the University of Applied Sciences in Jena.<\/p>\n<\/div>\n<p>&nbsp;<\/p>\n<\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<h3>Small and Almighty!<\/h3>\n<h6>The Easygraph offers the ideal solution to practices struggling with limited space. \u00a0Mounting directly on the slit lamp, this space-saving corneal topographer incorporates assessment of the cornea directly into the examination process. The Easygraph uses the same precise measuring technology as the Keratograph and is both a topographer and a keratometer combined into one unit. Numerous analysis and display formats support you in the quantitative classification of the cornea. The optionally available Contact Lens Fitting and OxiMap<sup>\u00ae<\/sup>\u00a0software modules can also be integrated to add confidence and trust to all contact lens consultations.<\/h6>\n","protected":false},"featured_media":1059,"comment_status":"open","ping_status":"closed","template":"","meta":{"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"product_cat":[17],"product_tag":[],"class_list":["post-1005","product","type-product","status-publish","has-post-thumbnail","product_cat-uncategorized","first","instock","shipping-taxable","product-type-simple","entry","content-bg","loop-entry"],"_links":{"self":[{"href":"https:\/\/visioncare.biz\/index.php?rest_route=\/wp\/v2\/product\/1005","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/visioncare.biz\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/visioncare.biz\/index.php?rest_route=\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/visioncare.biz\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1005"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/visioncare.biz\/index.php?rest_route=\/wp\/v2\/media\/1059"}],"wp:attachment":[{"href":"https:\/\/visioncare.biz\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1005"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/visioncare.biz\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=1005"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/visioncare.biz\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=1005"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}